Create Multi Node KVM Site on Equinix

Objective

This document provides instructions on how to install a Volterra multi-node Kernel-based Virtual Machine (KVM) site on Equinix Metal service. To learn more about Volterra sites, see Volterra Site.

Using the instructions provided in this document, you can deploy three Equinix bare metal servers with CentOS as the host operating system, create virtual machines on them, install Volterra software on those VMs, and then register the nodes into a multi-node cluster site.


Prerequisites


Configuration

In case of this deployment, the VoltMesh nodes require two interfaces attached. The first interface is the outside interface through which services running on the node can connect to the Internet. The second interface is the inside interface whose IP address is the default gateway IP address for all the application workloads and services present in the private subnets.

This image provides a high level view of the network topology:

Figure: VoltMesh Equinix Deployment Topology
Figure: VoltMesh Equinix Deployment Topology

Deploy Equinix Metal Servers

In case of deploying VoltMesh nodes on Equinix, first deploy three on-demand Equinix bare metal servers.

Note: Equinix Metal supports various types of server instance sizes and different CPU architectures. However, you can only deploy VoltMesh on x86 CPU architecture and not on Atom or ARM architectures.

Also, the following Equinix Metal instance sizes do not support the Layer 2 functionality required for a successful deployment:

  • ​​t1.small.x86
  • c1.small.x86
  • X1.small.x86

Perform the following steps:

Step 1: Start creating Equinix Metal Servers.
  • Log into the Equinix Console with your account credentials.
  • Click Servers > Choose Deploy Type > Deploy On Demand Servers.

Figure: Equinix Metal Location and Deploy Type
Figure: Equinix Metal Location and Deploy Type

  • Select a location and a server type.
Step 2: Set operating system and the number of servers.
  • Select CentOS and choose CentOS 7 as the operating system version.
  • Use the + button to set three servers and enter names for each of them.

Figure: Operating System and Server Names
Figure: Operating System and Server Names

Step 3: Optionally, add the user data and start deploying the servers.
  • Prepare the user data for configuring packages. The following is a sample:
#cloud-config

package_upgrade: true

packages:
    - qemu-kvm
    - qemu-img
    - virt-manager
    - libvirt
    - libvirt-python
    - libvirt-client
    - virt-install
    - virt-viewer
    - bridge-utils

runcmd:
   - systemctl start libvirtd
   - virsh net-undefine default
   - virsh net-destroy default
  • Enable the Add User Data option and paste the configuration you prepared.
  • Click the Deploy Now button to start deploying the servers.

Figure: Add User Data and Deploy Servers
Figure: Add User Data and Deploy Servers

Step 4: Verify that the servers are deployed.

After successful deployment, the Servers page displays the list of metal servers deployed.

Figure: Deployed Servers
Figure: Deployed Servers

Step 5: Request elastic IP block.

After creating the servers, you are required to configure IP addresses by obtaining an elastic IP address block.

  • Click IPs & Networks > IPs.

Figure: IPs & Networks Configuration
Figure: IPs & Networks Configuration

  • Select Public IPv4, choose a location, choose a quantity, and then click Submit Request.
  • Repeat for the Public IPv6 option.

Figure: Request Public IPv4 Block
Figure: Request Public IPv4 Block

  • Verify the IP addresses are assigned in the PROJECT IP ADDRESSES tab.

Figure: Verify the IP Address Blocks
Figure: Verify the IP Address Blocks

Step 6: Create VLANs.

The dual network interface controller (NIC) VoltMesh installation requires two VLANs, one for the internal interface and one for the external interface.

  • Click IPs & Networks > Layer 2.
  • Click Add New VLAN.
  • Set the description to indicate it is an internal VLAN and click Add.

Figure: Add Internal VLAN
Figure: Add Internal VLAN

  • Repeat the previous step to create another VLAN and set the description to indicate that it is an external VLAN.
  • Verify the created VLANs.

Figure: Created VLANs
Figure: Created VLANs


Convert Server Networking and Assign IPs/VLANs

When an Equinix Metal server is first deployed, there is a single-bonded interface. To support the dual NIC VoltMesh installation, the server networking type needs to be converted to Hybrid Bonded. By converting to hybrid bonded, the VLANs created in the previous section can be assigned to the bare metal instance.

Step 1: Convert networking to hybrid bonded mode.
  • Go to the Servers page and click on a server for which the networking is required to be converted.

Figure: Equinix Server List
Figure: Equinix Server List

The server overview page displays the networking information:

Figure: Server Overview
Figure: Server Overview

  • Select Network from the left menu to open the network page.
  • Click Convert to Other Network Type.

Figure: Convert Network Type
Figure: Convert Network Type

  • Select Hybrid in the network type selection window.
  • Select Bonded in the options and select one of the VLANs to assign.

Figure: Conversion to Hybrid Bonded with VLAN
Figure: Conversion to Hybrid Bonded with VLAN

Note: You can select any of the created VLANs. The second VLAN will be assigned in the next step. Therefore, the order of configuration does not matter.

  • Click ASSIGN NEW VLAN & CONVERT TO HYBRID NETWORKING.
Step 2: Assign second VLAN to the bare metal instance.
  • In the Network page, go to the Layer 2 section and click Add New Vlan.

Figure: Add New VLAN
Figure: Add New VLAN

  • In the Add New Vlan window, select the other VLAN in the Network field and click Add.

Figure: Add Second VLAN
Figure: Add Second VLAN

Step 3: Add elastic IP addresses to the bare metal instances.

Each metal instance requires two elastic IP addresses, one IP address for the network bridge interface and another for the VoltMesh external interface. To use an elastic IP address, it must be assigned to the metal instance.

After planning your address scheme, perform the following:

  • From the Elastic IP block that was allocated in the previous section, assign two /32 addresses.

In this example, the allocated IP block is 147.28.142.240/29 and the first or last IP addresses are not used, as they represent the network and broadcast addresses.

The following table shows the sample IP addresses this example sets:

Metal Instance Bridge IP Address Volterra External IP Address
VoltMesh-01 147.28.142.241 147.28.142.242
VoltMesh-02 147.28.142.243 147.28.142.244
VoltMesh-03 147.28.142.245 147.28.142.246
  • In the Network page for your server, click Assign New Elastic in the Elastic IPs section.
  • In the Add Elastic IP window, select Public IPv4 from the Address Type menu.
  • Select an option from the Block menu.
  • Select /32 from the Length menu.
  • Select an address from the Address/Range menu.
  • Click Add.

Figure: Add Elastic IP Address
Figure: Add Elastic IP Address

Figure: Elastic IP Addresses Added
Figure: Elastic IP Addresses Added

  • Repeat the above steps to add another IP address.
  • From the SERVER ACTIONS menu, select REBOOT to reboot and apply the changes.

Figure: Reboot the Instance
Figure: Reboot the Instance

  • Repeat the steps above for all your bare metal instances.

Deploy Volterra Site on Equinix Metal Servers

Deploying a multi-node Volterra site includes installing VoltMesh node on each of the metal servers. This involves configuring KVM on the instances, creating VMs with VoltMesh node images, performing post-installation configuration, and registering the VoltMesh nodes.

Configure KVM on Metal Instances

Configure the KVM hypervisor to support installation of VoltMesh software. Repeat this process for each bare metal instance.

Step 1: Connect to your instances using SSH.
  • To SSH into the first metal instance, click ... > SSH Info.

Figure: Obtain SSH Information
Figure: Obtain SSH Information

  • Click Copy to copy the SSH command displayed on the screen.

Figure: Copy SSH Command
Figure: Copy SSH Command

  • Using your preferred SSH client, log into the server as root.

Figure: Connect to Instance Using SSH
Figure: Connect to Instance Using SSH

Step 2: Edit system configuration to support VoltMesh cluster operation.
  • Open the sysctl.conf file for editing:
vi /etc/sysctl.conf
  • Add the following contents to the end of the file and save the changes:
vm.nr_hugepages = 1200
net.ipv4.ip_forward = 1
net.bridge.bridge-nf-call-ip6tables = 0
net.bridge.bridge-nf-call-iptables = 0
net.bridge.bridge-nf-call-arptables = 0
  • Load the bridge filter module:
modprobe br_netfilter
  • Apply the changes:
sysctl -p
Step 3: Download VoltMesh KVM software.
  • Copy the link to the latest software from the KVM Images page and use the wget command to download the image. The following is a sample command:
wget -O /var/lib/libvirt/images/volterra.iso https://vesio.blob.core.windows.net/dev/images/centos/7.2009.10-202106210938/vsb-ves-ce-certifiedhw-generic-production-centos-7.2009.10-202106210938.1624275431.iso
  • Wait for the download to complete. The download progress is indicated, and after completion, the command prompt is returned.

Figure: Download of VoltMesh KVM Software
Figure: Download of VoltMesh KVM Software

Step 4: Create a disk image for VoltMesh node.

Enter the following command:

qemu-img create /var/lib/libvirt/images/disk1.qcow2 30G
Step 5: Define KVM internal and external network interfaces.

Define the internal and external KVM network interfaces and apply configuration parameters. The format of the device name is bond0.<VLAN ID>. In this example, the VLAN IDs assigned to the Volterra internal and external VLANs are 1000 and 1001, respectively.

  • Create the internal VLAN interface file for editing:
vi /etc/sysconfig/network-scripts/ifcfg-bond0.1000
  • Add the following values and save the file:
DEVICE=bond0.1000
ONBOOT=yes
BOOTPROTO=none
BRIDGE=br0
VLAN=yes
  • Create the external VLAN interface:
vi /etc/sysconfig/network-scripts/ifcfg-bond0.1001
  • Add the following values and save the file:
DEVICE=bond0.1001
ONBOOT=yes
BOOTPROTO=none
BRIDGE=br1
VLAN=yes
Step 6: Configure internal VLAN interface network bridge IP addresses.

Define the Volterra internal VLAN interface network bridge IP addresses. The external Volterra interface uses public IP addresses. For internal interface, the RFC1918 private addresses are used. This step configures only the bridge IP address for each instance.

Note: The Volterra internal IP address configuration is performed within VoltConsole during a later step.

You can choose an IP address scheme per your choice for internal addressing, except the IP address space used by the bond0:0 interface. You can find the IP used by the bond0:0 interface by running the ip addr command.

In this example, the 192.168.100.0/24 address block is used. The following is the allocation scheme for this example:

Metal Instance Bridge IP Address Volterra Internal IP Address
VoltMesh-01 192.168.100.10 192.168.100.11
VoltMesh-02 192.168.100.20 192.168.100.21
VoltMesh-03 192.168.100.30 192.168.100.31

Note: Bridge IP Address is the SiteLocalInside gateway and Volterra internal IP address is the SiteLocalInside IP prefix within VoltConsole.

  • Create and open the internal bridge interface file for editing:
vi /etc/sysconfig/network-scripts/ifcfg-br0
  • Add DNS1, DNS2, IPADDR, and PREFIX settings and save the file. The following is a sample for the first metal instance:
DEVICE=br0
STP=no
TYPE=Bridge
BOOTPROTO=none
DEFROUTE=yes
NAME=br0
ONBOOT=yes
DNS1=8.8.8.8
DNS2=8.8.4.4
IPADDR=192.168.100.10 
PREFIX=24
  • Repeat the steps for each metal instance with the appropriate IP address based on your address scheme.
Step 7: Configure external VLAN interface network bridge IP addresses.

Define the Volterra external VLAN network bridge IP addresses. We recommend you use the IP address pattern as shown in the example below. Ensure not to use the first and last IP addresses in the /29 address range.

This example uses the elastic IP block 147.28.142.240/29.

Note: This step configures only the bridge IP address for each instance. Volterra external IP address configuration is performed within VoltConsole during a later step.

The following is the scheme used for this example:

Metal Instance Bridge IP Address Volterra External IP Address
VoltMesh-01 147.28.142.241 147.28.142.242
VoltMesh-02 147.28.142.243 147.28.142.244
VoltMesh-03 147.28.142.245 147.28.142.246

Note: Use the Elastic IP addresses from the block obtained in the Deploy Equinix Metal Servers chapter. The Bridge IP address is SiteLocal GW and the Volterra external IP address is the SiteLocal IP prefix within VoltConsole.

  • Create and open the internal bridge interface file for editing:
vi /etc/sysconfig/network-scripts/ifcfg-br1
  • Add DNS1, DNS2, IPADDR, and PREFIX settings and save the file. The following is a sample for first metal instance:
DEVICE=br1
STP=no
TYPE=Bridge
BOOTPROTO=none
DEFROUTE=yes
NAME=br1
ONBOOT=yes
DNS1=8.8.8.8
DNS2=8.8.4.4
IPADDR=147.28.142.241
PREFIX=29
  • Repeat the steps for each metal instance with the appropriate IP address based on your address scheme.
  • Reboot the metal instances and ping the elastic IP addresses to verify connectivity.

Create and Configure VoltMesh Virtual Machines

Create a VoltMesh virtual machine (VM), assign IP addresses to the internal and external interfaces, and configure the VoltMesh settings.

Step 1: Create a VoltMesh VM using the KVM CLI.
  • Enter the following command:
virt-install --name volterra \
--ram 16384 --vcpus=8 \
--os-variant=centos7.0 \
--network bridge=br1,model=virtio \
--network bridge=br0,model=virtio \
--accelerate \
--disk path=/var/lib/libvirt/images/disk1.qcow2,bus=virtio,cache=none,size=64 \
--cdrom /var/lib/libvirt/images/volterra.iso \
--noautoconsole --noreboot
  • To start the VM, enter the following command:
virsh start volterra
  • To start the VM automatically when the underlying host OS is started, enter the following command:
virsh autostart volterra
  • After the VM is started, use the KVM console to connect to it. The ID of the VM assigned by the KVM is required for this.
  • To obtain the ID assigned to the VM, enter the following command:
virsh list

Figure: Obtain the Virtual Machine ID
Figure: Obtain the Virtual Machine ID

Step 2: Connect to the local Volterra console.
  • Connect to the local console of the VM using the VM ID obtained in the previous step. The following is a sample command:
virsh console 1
  • At the login prompt, use admin as the username and Volterra123 as the password.

Figure: Volterra Local Console
Figure: Volterra Local Console

  • After logging in for the first time, choose a new password. Passwords must be at least 8 characters and include at least one upper case letter.
Step 3: Configure VoltMesh external interface.
  • Use the tab key to open the configuration menu and navigate to configure-network, and then press the enter key to start network configuration.
  • Use the arrow keys to navigate to the OUTSIDE option and press the space bar to select.

Figure: Select Outside Network Interface
Figure: Select Outside Network Interface

  • On the screen that follows, populate the fields as shown in the following image:

Figure: Configure Outside Interface
Figure: Configure Outside Interface

  • To confirm the changes, type y and then press the enter key.
Step 4: Configure VoltMesh internal interface.
  • Use the tab key to open the configuration menu and navigate to configure-network and press enter key to start network configuration.
  • Use the arrow keys to navigate to the INSIDE option and press the space bar to select.

Figure: Select Inside Network Interface
Figure: Select Inside Network Interface

  • On the screen that follows, populate the fields as shown in the following image:

Figure: Configure Inside Interface
Figure: Configure Inside Interface

  • Ensure that you set the primary interface as OUTSIDE.
  • To confirm the changes, type y and then press the enter key.
Step 5: Create or obtain a site token.

To configure VoltMesh and register your site, a site token is required. You can create a new token or use an existing token. This example shows steps to create a new token.

  • Log into VoltConsole.
  • Click Cloud and Edge Sites.
  • Click Manage > Site Management > Site Tokens.
  • Click Add site token.
  • Enter a name for the token and click Add site token.
  • Note down the generated token code under the UID column for your token.
Step 6: Configure other required VoltMesh settings.

At this point, you can either connect using the KVM console or use SSH to connect. In case of SSH, you can use the elastic IP address you configured in previous section. This example shows connecting using SSH.

  • Connect to the VoltMesh node using SSH and the elastic IP address for your instance.

Figure: Connect Using SSH
Figure: Connect Using SSH

  • Use the tab key to open the configuration menu and navigate to configure and press the enter key to begin configuration.
  • On the screen that follows, populate the fields as shown in the following image:

Figure: VoltMesh Node Configuration
Figure: VoltMesh Node Configuration

  • For What is your token and What is your site name?, enter the same name and token for all nodes. Use the token created in the previous step.
  • To confirm the changes, type y and then press the enter key. Your node will start to connect to VoltConsole for registration.
Step 7: Register your site.
  • Click Manage > Site Management > Registrations.
  • Choose your site from the list of sites displayed under the Pending Registrations tab.
  • Click the blue checkmark.
  • On the page that opens, set the Cluster Size to 3. Make sure that you set each node to the same cluster size.
  • Click Save and Exit to complete the registration process.
  • Repeat the above steps for each of the remaining nodes.

Note: It may take a few minutes for the registration process to complete and the site to change to ONLINE.